Vedere la pagina 161
Page 194 - 11. Automated playback (script files)
Pearl 2008 Manual - 16th July 2007
To reset the internal timer to 0, just press Enter.
B [Record script file] - This option lets you create a new script file as
described in section
11.1.1. If there is already a script file, the
Pearl will check you want to overwrite it (if not, select No and use
option C below to work on another file).
C [Select script file] - Lets you select which script file you want to
work on. The display shows a list of script files. Type the number
of the one you want using the numeric keypad, from 01-99, then
press Enter. To start with a new blank file, select any number
which is not on the list.
D [Edit script file] - Allows you to edit the current file, described in
detail in the Edit section on page
190.
E [Connect Timer] - Connects the timer to the script file. This will
cause steps to be executed when the event timecode matches the
timer. The option changes to Disconnect timer when selected, and
option F changes to Synchronise.
F [Next Step] - Moves on to the next step in the script file. The timer
is set to match the time of the step and the step is output. This
option changes to Synchronise when the timer is connected to the
script file; this allows the file to “catch up” with the timer by
skipping events.
G [Script File parameters] - Lets you set options for how the script
file is run. The display shows a list of the script files available, you
can select the current file using the cursor arrows or by entering
the script file number on the keypad. The menu options are:
A [Toggle the Global Autorun] - Enables Autorun, any file with
Autorun turned on using option C will run when the Pearl is
turned on
B [Toggle Loop mode] - Changes the Loop setting of the
current script file. Loop resets the timer to zero when the file
finishes. Only works with the internal timer.
C [Toggle the script file autorun] - Changes the Autorun
setting for the current script file. Global Autorun must also be
On. The Auto column will show “ON” when autorun is
enabled.
D [Set end-time from input] - Allows you to set the end-time
of the file from the numeric keypad
E [Set end-time from script] - Sets the end-time to the last
event in the file.
Vedere la pagina 161